Search
Close this search box.
Search
Close this search box.

1*8 ABS Module PLC Splitter

Product Highlights:

≤7.3dB Low Insertion Loss and ≤0.2dB Low Polarization Dependent Loss

Fully Passive Optical Branching Device

Fits Racks, Wall-mounted Boxes, Optical Distribution Boxes, etc.

1260~1650nm Broad Operating Wavelengths

 

Description:

Planar light wave circuit (PLC) splitter is a type of optical power management device that is fabricated using silica optical waveguide technology to distribute optical signals from Central Office (CO) to multiple premise locations.

 

Pigtailed ABS splitter is most commonly used in the PON networks. It provides the complete protection for inner optical components and cable, as well as designed for the convenient and reliable installation, but its volume is relatively large.

It’s mainly used for various connection and distribution box, ODF, 19”Rack mount patch panel or network cabinets.

Features:

  • Configuration Type: 1× 32, SC connector
  • 900μm ITU G.657A1 for fiber input/output
  • Low insertion loss ≤ 10.7dB
  • Low polarization dependent loss (PDL) ≤ 0.3dB
  • Operating wavelength: 1260 -1650nm
  • Return Loss 55/50dB
  • Wide Operating Temperature: -40 – 85°C
    support industry standardapplications
  • 1*8 ABS module size: 100*80*10mm

 

Application:

  • Optical Signal Distribution
  • Data Communications
  • Lan and CATV System
  • FTTX Deployment
  • FTTH Network
  • Passive Optical Networks (PON)
  • Measuring System and Laser System
  • DWDM and CWDM Systems

 

TELCORDIA 1209 & 1221 TEST RESULTS
Name of the test Condition Duration
 

Temperature- Humidity aging

 

85°C and 85% RH

 

7 days

Vibration 10 – 55Hz, 1.52mm double amplitude, in three axes 1 hour
Component Impact Test Impact of 500g (mass ≤ 0.125kg), 1ms , half sine pulse 2 impacts
Temperature Cycling Test -40 – 70°C, Ramp rate: 1°C /min, Dwell time > 15min 10 cycles
Temperature- Humidity cycling -40 – 85°C , between 10°C and 23°C – 85% RH, at 85°C – 20%RH,

between °C and 85°C – maintain a linear change in RH,

below 10°C – uncontrolled RH

14 days
Water Immersion 43 ± 2°C , PH 5.5 ± 0.5 7 days
Fiber Side Pull test 0.23 kg load, 90° angle , 2 directions 5 seconds
Fiber Side Pull test 0.45 Kg load for Single Input Fiber, 1.5 Kg load for 8 Fiber Ribbon Outputs 5 seconds

 

Application Solution:

Compact design, suitable for installation in outdoor fiber distribution box

The ABS PLC splitter supports the protection for inner componnents, it is suitable for reliable installation in your system design and manufacturing. Many of our OEM customers in the FTTH, FTTX, PON, GOPN prefer to use the ABS PLC splitter together with outdoor wall-mount ODF, 19” rack mount patch panel,ect.

 

 

 

Mechanical Drawing:

Dimension: 100(L) × 80 (W) × 10(H) mm